- Instruction – SIGMA AEP MOSFET
CYMA CM.125 SIGMA AEP MOSFET
CYMA CM.127 SIGMA AEP MOSFET
SIGMA MOSFET
ADVANCED MOSFET FOR AUTOMATIC ELECTRIC PISTOLS
INTERACTIVE MENU – description & usage
Table of contents
1. Menu handling
- Make sure the battery is unplugged and there is no BB in the chamber.
- Pull a trigger and hold it.
- Plug the battery.
- Release the trigger.
- Navigate through menu.
- Leave menu.
2. Settings description
3. Troubleshooting
4. Examples
5. Set BURST mode
6. Play current setting
7. Reset settings to default
1. Menu handling
- Haptic feedback
SIGMA will let you know about settings changes, or when your battery is low by means of gentle vibrations.
SIGMA uses gentle vibration haptic feedback for interfacing with user and low battery waring.
- Make sure the battery is unplugged and there is no BB in the chamber.
(NOTE: Entering the menu can only be done right after plugging in the battery.)
- Pull a trigger and hold it
- Plug the battery
- Release the trigger
If successful, SIGMA will vibrate 6 times with short delays.
Navigate through menu
After successfully entering settings menu user can navigate between options :
- Each short trigger press (shorter than 1 second) increases actual menu position by one and will be signalized by a single vibration,
- Each long trigger press (longer than 1.5 seconds) will set a setting that corresponds to a number of provided short trigger pulls,
- After long press, SIGMA will play current setting with vibrations. E.g. if 5 short presses were provided (menu position no. 5), SIGMA will vibrate 5 times. After a short delay, 2 vibrations will be played as an indication of saved setting. Has this been done, user can input next command.
- Leave menu
In order to leave menu either unplug the battery or choose settings number 10.
When leaving menu by choosing relevant setting (10 short trigger pulls), SIGMA will indicate that by vibrating 6 times with short breaks.
2. Settings description
Setting | Description |
1 | Set AUTO |
2 | Set BURST |
3 | Reserved/Inactive (will set BURST Mode) |
4 | Reserved/Inactive (will do nothing) |
5 | Set Ni-MH battery |
6 | Set Li-Po battery (2S) |
7 | Set Li-Po battery (3S) |
8 | Play current settings |
9 | Reset settings to default |
10 | Exit menu (AEP will become ready to use) |
- Set AUTO Sets AUTO mode.
- Set BURST Sets BURST mode. Number of shots may vary from 2 to 4, depending on the battery charge level.
- Inactive (will set BURST Mode) This feature is currently not active. Setting it will set BURST mode.
- Inactive This feature is currently not active. Setting it brings no result.
- Set Ni-MH battery Sets Ni-MH battery. A low battery alarm will be reported under 6V.
- Set Li-Po (2S) battery Sets Li-Po (2S) battery. A low battery alarm will be reported under 6V.
- Set Li-Po (3S) batterySets Li-Po (3S) battery. A low battery alarm will be reported under 9V.
- Play current settings Plays current settings in the following format:
- X vibrations (setting number)
- 0.5 second pause
- state (2 vibrations if SET, 4 vibrations if NOT SET)
- 1 second pause <repeat until end of settings>
- e.g. 2 vibrations followed by 4 vibrations will mean that setting number 2 is NOT SET.
- X vibrations (setting number)
Reset settings to default – Resets the settings to default:
1 | AUTO | SET |
2 | BURST | NOT SET |
3 | Inactive | NOT SET |
4 | Inactive | NOT SET |
5 | Ni-MH battery | SET |
6 | Li-Po (2S) battery | NOT SET |
7 | Li-Po (3S) battery | NOT SET |
Leave menu – Leaves interactive menu. Indicates it by 6 vibrations. From this moment replica will shoot when the trigger is pulled (normal operation).
3. Troubleshooting
If you got lost and don’t know where you are at with the menu -simply unplug the battery and repeat the process. You may also choose a “Play current settings” or “Reset settings to default”.
4. Examples
- Set BURST mode
- make sure the battery is unplugged and there is no BB in the chamber,
- pull a trigger and hold it,
- plug in the battery,
- release the trigger and wait for confirmation ,
SIGMA should vibrate 6 times - select menu:
- perform 2 short (< 1s) trigger presses,
SIGMA should vibrate once after each short press as a confirmation - perform 1 long ( > 1.5s) trigger press,
SIGMA should vibrate 2 times (selected menu no. 2)
After that, 2 additional vibrations will be given to confirm
- perform 2 short (< 1s) trigger presses,
- leave menu:
- perform 10 short (< 1s) trigger presses,
SIGMA should vibrate once after each short press as a confirmation - perform 1 long ( > 1.5s) trigger press,
SIGMA should vibrate 10 times as an indication of selected menu (no. 10)
After that, 6 additional vibrations will be given (menu was left)
- perform 10 short (< 1s) trigger presses,
5. Play current settings
- make sure the battery is unplugged and there is no BB in the chamber,
- pull a trigger and hold it,
- plug the battery,
- release the trigger and wait for vibrations,
SIGMA should vibrate 6 times (menu was entered) - select menu:
- perform 8 short (< 1 second) trigger presses,
SIGMA should vibrate once after each short press as a confirmation - perform 1 long ( > 1.5 second) trigger press,
SIGMA should vibrate 8 times (selected menu no. 8)
After that, 2 additional vibrations will be given to confirm
- perform 8 short (< 1 second) trigger presses,
- leave menu:
- perform 10 short (< 1s) trigger presses,
SIGMA should vibrate once after each short press as a confirmation - perform 1 long ( > 1.5s) trigger press,
SIGMA should vibrate 10 times as an indication of selected menu (no. 10)
After that, 6 additional vibrations will be given (menu was left)
- perform 10 short (< 1s) trigger presses,
6. Reset settings to default
- make sure the battery is unplugged and there is no BB in the chamber,
- pull a trigger and hold it,
- plug the battery,
- release the trigger and wait for vibrations,
SIGMA should vibrate 6 times - select menu:
- perform 9 short (< 1s) trigger presses,
SIGMA should vibrate once after each short press as a confirmation - perform 1 long ( > 1.5s) trigger press,
SIGMA should vibrate 9 times (selected menu no. 9)
After that, 2 additional vibrations will be given to confirm
- perform 9 short (< 1s) trigger presses,
- leave menu:
- perform 10 short (< 1s) trigger presses,
SIGMA should vibrate once after each short press as a confirmation - perform 1 long ( > 1.5s) trigger press,
SIGMA should vibrate 10 times as an indication of selected menu (no. 10)
After that, 6 additional vibrations will be given (menu was left)
- perform 10 short (< 1s) trigger presses,